MCB (pemutus sirkuit miniatur)

Karakteristik
• Dinilai saiki ora luwih saka 125 A.
• Karakteristik perjalanan biasane ora luwes.
• Operasi termal utawa termal-magnetik.

What is the difference between MCB, MCCB, ELCB, and RCCB34

What is the difference between MCB, MCCB, ELCB, and RCCB32

MCCB (pemutus sirkuit kasus cetakan)

Karakteristik
• Dirating saiki nganti 1600 A.
• Perjalanan saiki bisa diatur。
• Operasi termal utawa termal-magnetik.

What is the difference between MCB, MCCB, ELCB, and RCCB400

What is the difference between MCB, MCCB, ELCB, and RCCB402

Pemutus sirkuit udara

Karakteristik
• Dinilai saiki nganti 10.000 A.
• Karakteristik perjalanan asring bisa diatur kalebu ambang lan telat perjalanan sing bisa dikonfigurasi.
• Biasane dikontrol kanthi elektronik — sawetara model kontrol mikroprosesor.
• Asring digunakake kanggo distribusi tenaga utama ing pabrik industri gedhe, ing endi breaker disusun ing pager tarik supaya gampang dirampungake.

Pemutus sirkuit vakum

Karakteristik
• Kanthi nilai saiki nganti 3000 A,
• Breaker kasebut ngganggu busur ing botol vakum.
• Iki uga bisa ditrapake nganti 35.000 V. Pemutus sirkuit vakum cenderung duwe wektu pangarep-arep luwih suwe ing antarane pamriksan tinimbang pemutus sirkuit udara.

RCD (residual current device / RCCB (residualcurrent circuit breaker)

Karakteristik
• Tahap (baris) lan kabel Neutral disambungake liwat RCD.
• Plancongan sirkuit nalika ana kesalahan global.
• Jumlah aliran saiki liwat fase (garis) kudu bali liwat netral.
• Ndeteksi kanthi RCD. ora cocog antara rong aliran sing mili liwat fase lan netral ndeteksi -RCD lan nempuh sirkuit sajrone 30Miliseconed.
• Yen omah duwe sistem bumi sing nyambung karo rod bumi lan dudu kabel sing mlebu utama, mula kabeh jaringan kudu dilindhungi RCD (amarga sampeyan ora bisa entuk arus kesalahan sing cukup kanggo ngeterake MCB)
• RCD minangka bentuk proteksi kejut sing efektif banget
Sing paling akeh digunakake yaiku 30 mA (milliamp) lan 100 piranti mA. Aliran saiki 30 mA (utawa 0,03 amp) cukup cekap saengga angel banget kanggo nampa kejutan sing mbebayani. Malah 100 mA minangka tokoh sing cukup cilik yen dibandhingake karo arus sing bisa mili ing kesalahan bumi tanpa proteksi kaya ngono (atusan amp)
RCCB 300/500 mA bisa digunakake yen mung mbutuhake perlindungan geni. contone, ing sirkuit lampu, yen risiko kejut listrik sithik.

Watesan saka RCCB

• RCCB elektromekanik standar dirancang kanggo operasi ing bentuk gelombang pasokan normal lan ora bisa dijamin bisa dioperasikake kanthi ora ana bentuk gelombang standar sing ngasilake beban. Sing paling umum yaiku gelombang gelombang sing dilerifikasi setengah gelombang sing kadang disebut pulsating dc sing digawe dening piranti kontrol kacepetan, semi konduktor, komputer lan uga dimmer.
• RCCB sing dimodifikasi khusus kasedhiya sing bakal digunakake ing ac normal lan pulsating dc.
• RCD ora menehi perlindungan saka kakehan saiki: RCD ndeteksi ora seimbang ing arus urip lan netral. Beban sing akeh saiki, sanajan gedhe, ora bisa dideteksi. Minangka panyebab umum masalah karo wong anyar kanggo ngganti MCB ing kothak sekring nganggo RCD. Iki bisa ditindakake kanthi upaya nambah perlindungan kejutan. Yen ana kesalahan netral-nyata (sirkuit cendhak, utawa kakehan), RCD ora bakal kliwat, lan bisa uga rusak. Ing prakteke, MCB utama ing papan kasebut bisa uga plancongan, utawa sekering layanan, mula kahanane ora bisa nyebabake musibah; nanging bisa uga ora kepenak.
• Saiki sampeyan bisa entuk MCB lan lan RCD ing unit siji, diarani RCBO (pirsani ing ngisor iki). Ganti MCB karo RCBO kanthi rating sing padha umume aman.
• Kesalahan saka RCCB: Ganti beban listrik sing tiba-tiba bisa nyebabake aliran arus sing sithik menyang bumi, utamane ing peralatan lawas. RCD sensitif banget lan operasi cepet banget; bisa uga plancong nalika motor mesin pembeku lawas dipateni. Sawetara peralatan kondhang `` bocor ', yaiku ngasilake aliran arus konstan ing bumi. Sawetara jinis peralatan komputer, lan televisi sing gedhe, dilaporake bisa nyebabake masalah.
• RCD ora bakal nglindhungi outlet soket sing dipasang kanthi terminal urip lan netral kanthi cara sing salah.
• RCD ora bakal nglindhungi saka overheating sing diasilake nalika konduktor ora diaco menyang terminal.
• RCD ora bakal nglindhungi kejutan sing netral, amarga arus urip lan netral imbang. Dadi, yen sampeyan tutul konduktor langsung lan netral sekaligus (contone, kalorone terminal sing pas lampu), sampeyan isih bakal kejut.

ELCB (Pemecah Sirkuit Kebocoran Bumi)

Karakteristik
• Fase (baris), kabel Netral lan Bumi sing disambungake liwat ELCB.
• ELCB digunakake adhedhasar arus bocor Bumi.
• Wektu Operasional ELCB:
• Watesan saiki sing paling aman sing bisa ditindakake Badan Manungsa yaiku 30ma detik.
• Umpamane Resistensi Awak Manungsa 500Ω lan voltase sing lemah yaiku 230 Volt.
• Saiki awak bakal 500/230 = 460mA.
• Mula ELCB kudu dioperasikake ing 30maSec / 460mA = 0.65msec.

What is the difference between MCB, MCCB, ELCB, and RCCB4845

RCBO (Residual Circuit Breaker with OverLoad)

• Sampeyan bisa entuk MCB gabungan lan RCCB ing siji piranti (Residual Current Breaker with Overload RCBO), kepala sekolah padha, nanging luwih akeh gaya pedhot sing dipasang dadi siji paket.

What is the difference between MCB, MCCB, ELCB, and RCCB5287

Beda antara ELCB lan RCCB

• ELCB minangka jeneng lawas lan asring nuduhake piranti sing dioperasikake kanthi voltase sing wis ora kasedhiya lan disaranake sampeyan ganti yen sampeyan nemokake.
• RCCB utawa RCD minangka jeneng anyar sing nemtokake operasi sing saiki (mula jeneng anyar kanggo mbedakake saka voltase sing dioperasikake).
• RCCB anyar paling apik amarga bakal nemokake kesalahan bumi. Jinis voltase mung bisa ndeteksi kesalahan bumi sing bali liwat kawat bumi utama mula mula ora digunakake.
• Cara gampang kanggo ngandhani lelungan sing dioperasikake karo voltase lawas yaiku nggoleki kabel bumi utama sing disambungake.
• RCCB mung bakal duwe sambungan garis lan netral.
• ELCB digunakake adhedhasar arus bocor Bumi. Nanging RCCB ora nduwe sensasi utawa konektivitas Bumi, amarga dhasar Fase saiki padha karo arus netral ing fase tunggal. Mula saka iku RCCB bisa lelungan nalika kalorone beda lan tahan nganti kalorone padha. Aliran arus netral lan fase beda-beda tegese aliran saiki liwat Bumi.
• Pungkasane, kalorone bisa digunakake kanthi padha, nanging konektivitas yaiku bedane.
• RCD ora kudu mbutuhake koneksi bumi dhewe (mung ngawasi sing urip lan netral). Kajaba iku, pendeteksi arus saiki menyang bumi sanajan ana peralatan tanpa bumi dhewe.
• Iki tegese RCD bakal terus menehi perlindungan kejut ing peralatan sing duwe bumi sing rusak. Properti kasebut sing nggawe RCD luwih populer tinimbang para pesainge. Contone, pemutus sirkuit bocor bumi (ELCB) akeh digunakake udakara sepuluh taun kepungkur. Piranti kasebut ngukur voltase ing konduktor bumi; yen voltase iki dudu nol iki nuduhake kebocoran saiki menyang bumi. Masalahe yaiku ELCB mbutuhake sambungan bumi sing apik, uga peralatan sing dilindhungi. Asile, panggunaan ELCB wis ora disaranake maneh.

Pilihan MCB

• Karakteristik pertama yaiku kakehan sing tujuane kanggo nyegah kabel sing ora sengaja ing kahanan sing ora ana kesalahan. Kacepetan tripping MCB bakal beda-beda kanthi tingkat kakehan. Iki biasane ditindakake kanthi nggunakake piranti termal ing MCB.
• Karakteristik nomer loro yaiku proteksi kesalahan magnetik, sing tujuane dioperasikake nalika kesalahan wis tekan level sing wis ditemtokake lan kanggo MCB sajrone sepuluh detik. Tingkat perjalanan magnetik iki menehi MCB karakteristik kaya ing ngisor iki:

Jinis

Tripping Saiki

Wektu Operasi

Jinis B

3 Nganti 5 wektu mbukak saiki

0,04 Nganti 13 Sek

Jinis C

5 Nganti 10 kaping saiki mbukak

0,04 Nganti 5 Det

Jinis D

10 Nganti 20 kali mbukak saiki

0,04 Nganti 3 Det

• Karakteristik nomer telu yaiku proteksi sirkuit cendhak, sing tujuane kanggo nglindhungi kesalahan sing abot, bisa uga ewonan amp sing disebabake kesalahan sirkuit cendhak.
• Kapabilitas MCB kanggo operate miturut kahanan kasebut menehi rating sirkuit cendhak ing Kilo amps (KA). Umume kanggo unit konsumen, level kesalahan 6KA cukup yen kanggo industri kapabilitas cacat 10KA utawa ndhuwur bisa dibutuhake.

Karakteristik sekring lan MCB

• Sekring lan MCB dirating ing ampli. Rating amp sing diwenehake ing sekring utawa awak MCB yaiku jumlah arus sing bakal terus diterusake. Iki biasane diarani arus sing dirating utawa saiki nominal.
• Akeh wong sing mikir yen saiki ngluwihi arus nominal, piranti kasebut bakal cepet. Dadi yen rating 30 amp, saiki ampli 30.00001 bakal kesasar, bener? Iki ora bener.
• Sekring lan MCB, sanajan arus nomine padha, duwe sifat sing beda banget.
• Contone, Kanggo 32Amp MCB lan 30 Amp Fuse, supaya bisa kesandung ing 0,1 detik, MCB mbutuhake arus 128 amp, nalika sekering mbutuhake 300 amp.
• Sekring kasebut kanthi jelas mbutuhake luwih akeh arus kanggo nyebul ing wektu kasebut, nanging sok dong mirsani sepira luwih gedhe kaloro arus kasebut tinimbang rating '30 amp 'sing ditandhani saiki.
• Ana kemungkinan cilik yen sajrone sebulan, sekring 30-amp bakal mlaku nalika nggawa 30 amp. Yen sekring wis sawetara kakehan sadurunge (sing bisa uga ora ditemokake), kemungkinane luwih akeh. Iki nerangake kenapa sekring bisa 'jotosan' tanpa sebab sing jelas.
• Yen sekring ditandhani '30 amps ', nanging sejatine 40 amp nganti luwih saka sak jam, kepiye cara bisa menehi sebutan "30 amp" sekring? Wangsulane yaiku, karakteristik kabotan sekring dirancang kanggo cocog karo kabel-kabel modern. Contone, kabel sing terisolasi PVC modern bakal ana sing kakehan 50% sajam, mula bisa uga fiuse uga.